One Stop

Level 2 specification

NR/L2/TEL/30080

Specification for the Maintenance of Whiteley PETS (formerly NR/WI/TEL/30080)

Issue 3, 7 June 2014

Maintenance regime for Whiteley public emergency telephone systems (PETS) at level crossings: 3 monthly crossing phone checks and call tests (labels, sign, off-hook alarm, emergency override), yearly control equipment checks, and battery checks on Yuasa NP12-12 cells with internal resistance and voltage limits.

Clause map — what each clause deals with

1PurposeMaintaining Whiteley PETS reduces deterioration failures and finds faults early
2ScopeCovers Whiteley PETS at road/rail crossings with charger, batteries, phones and tail cables, and the staff who maintain them
3ResponsibilitiesAgree work with the signaller, battery PPE and gas precautions, ESD, report defects, label faulty phones, record actions on work return
Appendix AMaintenance of Whiteley PETSFrequency table (3 monthly phones, yearly control equipment, batteries 6 or 12 monthly by climate control) and the service task lists
Appendix A Service ACrossing End Phones CheckEach crossing phone: access, 3-sided sign, label content, housing and post, backlight, tail cable, handset; call test, off-hook alarm test and emergency override test
Appendix A Service BControl EquipmentCrossing and standalone signal box end control units: access, alarms cleared first, cable entry, wiring, terminations and earthing
Appendix A Service CBatteriesFuse, straps and terminals, room temperature range, internal resistance test and per-cell voltage against tolerance tables for Yuasa NP12-12, terminal cleaning