One Stop

Level 2 specification

NR/L2/TEL/30119

Specification for the Maintenance of Public Address PCs (formerly NR/WI/TEL/30119)

Issue 2, March 2009

Maintenance specification for the PCs that drive station public address announcements: maintainer duties in public areas and a single service (twice a year at the busiest stations (major, managed and Section 12), yearly at other sites) covering cleaning, fans, filters, cabling and reboot checks.

Clause map — what each clause deals with

1PurposeSets out a routine inspection regime for telecoms maintainers looking after public address PCs, aiming to catch wear and defects before they cause service failures
2ScopeCovers anyone maintaining public address PCs used by Network Rail or the Station Facilities Operator (SFO)
3Definitions (in addition to those defined in NR/L2/TEL/31002)Short list of abbreviations (PC, SFO, VDU); other terms come from the parent telecoms maintenance standard NR/L2/TEL/31002
4ResponsibilitiesMaintainer must avoid disturbing safety-related or in-use equipment without user agreement, protect the public in station areas, avoid peak hours, and report defects via fault control
Appendix APublic Address PC'sService A every 6 months at Major, Managed and Section 12 stations, yearly elsewhere: clean outside and inside, check fans and filters, tidy cables, reboot and confirm service, then label and log