One Stop

Level 2 specification

NR/L2/TEL/30120

Specification for the Maintenance of Public Address Systems (formerly NR/WI/TEL/30120)

Issue 2, March 2009

Maintenance specification for station public address (PA) systems: scope boundaries with the PA PC and power plant specs, maintainer duties in public areas, and a yearly service covering alarms, test announcements, zones, speakers, cabinets, cabling and records.

Clause map — what each clause deals with

1PurposeSets out a routine inspection regime for telecoms maintainers looking after public address systems, aiming to catch wear and defects before they cause service failures
2ScopeCovers anyone maintaining station PA systems for Network Rail or the SFO; PA PCs and the PA power supplies, UPS and batteries are handled by separate maintenance specs
3Definitions (in addition to those defined in NR/L2/TEL/31002)Short list of abbreviations (PC, SFO); other terms come from the parent telecoms maintenance standard NR/L2/TEL/31002
4ResponsibilitiesMaintainer must avoid disturbing safety-related or in-use equipment without user agreement, protect the public in station areas, avoid peak hours, and report defects via fault control
Appendix AMaintenance of Public Address SystemsYearly Service A: alarms, audible test announcements, zone controls, speaker condition and aim, local mic and chimes, cabinet seals and locks, exposed cables, terminations, site records, corrosion, then label and log