One Stop

Specification (legacy numbering)

NR/SP/TEL/30031

Signal Box Telephone Concentrator System - Design and Application Requirements (formerly RT/E/S/30031)

Issue 2, April 2006

Design rules for signal box telephone concentrators: which operator-facing features need Network Rail approval, spare capacity and expansion, spreading SPTs across line cards, designing out call blocking at peak failure traffic, and special handling of level crossing and SPT circuits.

Clause map — what each clause deals with

1PurposeStates the document sets minimum design rules for signal box concentrators and how operating rules are applied to them
2ScopeApplies to new concentrator systems in Network Rail signal boxes and to later changes to them
3Reference documentationRefers to the main concentrator system specification NR/SP/TEL/30002
4DefinitionsDefines concentrator, handset, key, lineside telephone, MMI, operator, signal box, SPT and what counts as the system
5.1Approval of Operator's FacilitiesLists site-specific operator features Network Rail must sign off, like MMI position, key labels and colours, alerts, cord lengths and circuit reallocation
6.1IntroductionIntroduces the minimum design criteria for concentrator systems
6.2System ExpansionRequires fitted spare line card capacity (10%) and capability to grow further (30%) without major rework
6.3Circuit AllocationAvoid putting two neighbouring SPTs on the same line card so one card failure does not lose both
6.4Call Blocking Risk Reduction RequirementsSystem must not block calls even at worst case, every train stopped calling during degraded working; crossing calls never blocked; calculations recorded and reviewed
7.1IntroductionGeneric telephone rules sit in NR/SP/TEL/30002; this section adds extra rules for particular operational circuits
7.2Level Crossing TelephonesCalls from AHBC/ABCL public phones get a distinctive alert that is not silenced, a differently coloured key, and a latched indication until acknowledged
7.3Signal Post TelephonesSPT calls cannot be put on hold or into a conference
7.4Multiple AccessA circuit may appear on more than one operator position, but SPT and level crossing circuits are not to be shared

Standards this one points to