One Stop

Specification (legacy numbering)

NR/SP/TEL/30032

Positioning and Labelling of Lineside Telephones (formerly RT/E/S/30032)

Issue 3, April 2006 · Lineside telephones & NTPs

How NR applies Railway Group Standard GE/RT8048 to the positioning and labelling of lineside telephones

Clause map — what each clause deals with

1PurposeHow NR applies Railway Group Standard GE/RT8048 to the positioning and labelling of lineside telephones
2ScopeApplies to the position and labelling of lineside telephones (SPTs, direct lines, dialling phones)
4DefinitionsDirect line, identification label, information label, position of safety and the other terms used
5ExclusionsLevel crossing telephones are excluded — covered by GI/RT7012
6.1Compliance Through Re-Signalling SchemeWhen the Territory Telecoms Engineer may let positioning compliance wait for an impending re-signalling scheme
6.2Telecoms Lineside Telephones Site Assessment CommitteeThe site assessment committee that agrees positions for telephones installed since April 2002
6.3.1Signal Post TelephonesPositioning of SPTs relative to the signal — the GE/RT8048 rules plus NR's amplifications, and when the committee may pick an alternative position
6.3.2Other Direct Lines to Signal BoxesPositioning of other direct lines to signal boxes
6.3.3Direct Lines to ECRsDirect lines to electrical control rooms — position of safety, GE/RT8048 B4.1, recorded per clause 8
6.3.4Telephones with Dialling facilitiesDialling telephones — position of safety, GE/RT8048 B4.1, recorded per clause 8
7.1GeneralAll lineside telephones carry labels and signs to GE/RT8048 as amplified here; labelling status is recorded
7.2SPT Information labellingMinimum content of the SPT information label (GE/RT8048 B5.2) and the suggested layout in Appendix 1
7.3SPT Identification Labelling and Additional SignsSPT identification labels and the extra 'Signal Post Telephone' sign when the SPT is on the opposite side of the line to its signal
7.4Information labels for Other Direct Lines to Signal boxesInformation labels for other direct lines to signal boxes, with OS grid reference format
7.5Identification labels for Other Direct Lines to Signal BoxesIdentification labels for other direct lines to signal boxes
7.6Information labels for Direct Lines to Electrical control RoomsInformation labels for direct lines to ECRs, with OS grid reference format
7.7Identification Labels for Direct Lines to Electrical Control RoomsIdentification labels for direct lines to ECRs
7.8Information labels for Telephones with Dialling FacilitiesInformation labels on dialling telephones — grid reference and easting/northing formats
7.9Identification labels for Telephones with Dialling FacilitiesIdentification labels on dialling telephones — the black-on-white handset symbol for Railnet/PTO phones
7.11Telephones not in Service / FaultyLabelling telephones not yet commissioned or faulty — warning sign or black-on-yellow NOT IN SERVICE tape
8RecordsRecords kept for every telephone by the TTE, paper or electronic, and how long
9Construction of Telephone UnitsPoints to GE/RT8048 clause B9 for construction of the telephone units
Appendix 1Example of an information label for SPTs and other direct lines to signal boxesExample information label layout for SPTs and direct lines

Standards this one points to