What is the XMC20?
At a glance
A multiplexer subrack that carries telephone, voice frequency, low-speed data and E1 circuits over the FTNx packet network. It comes in three sizes: XMC25 (21 slots), XMC23 (8 slots) and XMC22 (4 slots). The maker was KeyMile, then ABB, now Hitachi.
Why: Many railway circuits are not Ethernet: signal post telephones, voice frequency circuits, serial data and 64 kbit/s data links. The XMC20 gives these circuits a port on the new network. It replaced the older PDH multiplexers in FTN nodes.
Where: In FTNx nodes: equipment rooms, REBs and control centres. A control card (COGE5) goes in the subrack, and one interface card for each circuit type: SUPM1 and TUXA1 for telephones, TUEM1 for voice frequency, TUGE1 for 64 kbit/s G.703, TUDA1 for serial data, SELI8 for E1.
Where the rules are
- NR/L2/TEL/30003 cl 1why equipment connected to lineside copper is immunity tested (the reason for the FIL16 filter)
What to order
- XMC25 subrack with ED cover, 19" 8 HU, 21 slots, 10GbE and GbE double star, TDM Bus. · Hitachi ABB Power Grids · 3ZNR-47950215
- XMC23 subrack with ED cover. 19" 4 HU, 8 slots, 10GbE and GbE double star, TDM Bus. · Hitachi ABB Power Grids · 3ZNR-47950118
- XMC22 subrack with ED cover. 19" 2,2 HU, 4 slots and 1GbE access. · Hitachi ABB Power Grids · 3ZNR-47950193
- COGE5 card: XMC20 central (control) card, 2 SFP+ and 3 RJ45 Ethernet ports · Hitachi ABB Power Grids · 3ZNR-47900595
- SUPM1 card (XMC20): 16 subscriber (FXS) telephone ports · Hitachi ABB Power Grids · 3ZNR-47900404
- TUXA1 card (XMC20): 12 exchange (FXO) ports · Hitachi ABB Power Grids · 3ZNR-47900277
- TUEM1 card (XMC20): 8 voice frequency ports, 2-wire or 4-wire, with E&M · Hitachi ABB Power Grids · 3ZNR-47900269
- TUGE1 card (XMC20): 64 kbit/s G.703, 8 co-directional or 2 contra-directional ports · Hitachi ABB Power Grids · 3ZNR-47900560
- TUDA1 card (XMC20): 4 serial data ports (X.24/V.11, V.24/V.28, V.35, RS-485) · Hitachi ABB Power Grids · 3ZNR-47900358
- SELI8 card (XMC20): 8 E1 (2 Mbit/s G.703) ports · Hitachi ABB Power Grids · 3ZNR-47900129
Sign up free to see the PADS number on each part page. More in the parts finder
On the drawing
The network design from NR gives the subrack, the slot and the port for each circuit. The site design shows the card, its cable and where the cable terminates (MDF block or patch panel).
Also called: XMC, KeyMile XMC, MileGate, multiservice access unit
Guidance in our own words. Read the current issue of each standard before you use it for a design.