Level 2 specification

NR/L2/TEL/30179

Design of Fibre Distribution Systems and Fibre End-User Connections

Issue 2, 05 September 2026 · Fibre design

What the standard is for: how end users are connected to NR's fibre without harming trunk capacity. Issue 2 note: commercial demand is now long-haul fibre, so new FIPs and FATs are not expected to be deployed — 30179 is for upkeep of, and designs interfacing with, existing FIP/FAT assets (e.g. the TPI area), and most of its design rules are now worded as guidance (should) rather than mandatory (shall)

Clause map — what each clause deals with

1PurposeWhat the standard is for: how end users are connected to NR's fibre without harming trunk capacity. Issue 2 note: commercial demand is now long-haul fibre, so new FIPs and FATs are not expected to be deployed — 30179 is for upkeep of, and designs interfacing with, existing FIP/FAT assets (e.g. the TPI area), and most of its design rules are now worded as guidance (should) rather than mandatory (shall)
2ScopeWho it applies to: anyone designing or building NTPs, distribution systems or end-user fibre connections
3Accountable and Responsible RolesAccountable and responsible roles for competent design and survey
4Definitions and AbbreviationsAbbreviations and definitions (FIP, FAT, NTP, S-ODF; HCFC now defined as 288 fibres or more, with 432 the default trunk cable)
5.1GeneralOverview of NR's fibre asset — FTN and HCFC
5.2Ancillary InformationBackground on why the 24-fibre FTN cannot carry everything
6.1HCFC ArchitectureHow the HCFC trunk architecture is meant to be exploited by distribution systems
6.2Distribution Systems ArchitectureWhen a distribution system is used versus a direct connection at a joint or S-ODF
7.1GeneralThe principle that end-user fibres are not fusion-spliced to trunk, spur or distribution cables — demountable connections (NTP, pluggable, test point) instead; guidance wording since Issue 2
7.2.1GeneralFibre Interface Points — the pluggable connection between end user and trunk
7.2.2FATsFibre Access Terminals for external end-user connections
8.1GeneralWhat a distribution system consists of — cables between a joint/S-ODF and the NTPs
8.2.1GeneralWhen a direct connection is used instead of a spur or distribution cable
8.2.2Spur CablesSpur cables — where they are laid and what they connect into
8.2.3Distribution cablesDistribution cables — connected at both ends into existing joints/ODFs
8.3Network Termination Points (NTPs)Network Termination Points — the demarcation at the end of NR's fibre
8.5Guidance on Conversion of a Joint to a S-ODFConverting a congested joint into an S-ODF